Kitchen Ventilation & Makeup Air
The need for makeup air depends on the hood CFM, the house tightness, and the combustion appliances. A 300 CFM hood in a leaky house may be fine. A 900 CFM hood in a new tight house may need a dedicated makeup-air system. The right answer comes from a blower-door test and a load calculation, not a rule of thumb.
At a glance
- Planning cost
- $800–$6,000
- Timeline
- 3 days
- Heat / moisture
- 8/10
- Slip / stain
- 8/10
- Maintenance
- Moderate
Why makeup air matters
A hood is an exhaust fan. It moves air out of the kitchen, and that air has to be replaced. In a leaky house, the replacement air comes through gaps around windows and doors. In a tight house, it may come from a crawlspace, an attic, or a water heater flue.
Backdrafting is the dangerous version. A negative pressure can pull combustion gases from a gas water heater or furnace into the house. A carbon monoxide alarm is not a substitute for a proper pressure test and a makeup-air plan.
| Hood CFM | House tightness | Makeup air |
|---|---|---|
| 300 | Leaky | Usually not required |
| 300 | Tight | Test; a small intake may be enough |
| 600 | Tight | Likely required |
| 900+ | Any | Plan a system; test the pressure |
Signs of a pressure problem
A door that is hard to open when the hood is running is a sign of negative pressure. A water heater flue that spills or a fireplace that smokes is a serious sign. A hood that seems weak despite a high CFM may be starved for air.
Do not ignore a smell of exhaust gas or a CO alarm. Turn off the hood, open a window, and call a qualified technician. A pressure problem is a safety issue, not a comfort issue.
- The hood is noisy but does not capture smoke.
- A door is hard to open when the hood runs.
- The water heater flue spills or the fireplace smokes.
- A CO alarm sounds when the hood is on.
Sizing the makeup air
A makeup-air system should provide enough air to balance the hood without over-pressurizing the house. The exact size depends on the hood CFM, the house volume, the tightness, and the combustion appliances. An engineer or a qualified HVAC contractor should calculate it.
A common approach is to provide makeup air at 80 to 100 percent of the exhaust CFM, tempered and filtered. A smaller intake can work if the house is leaky, but it should be tested. A motorized damper interlocked with the hood prevents backdrafts when the hood is off.
| Component | Purpose | Note |
|---|---|---|
| Intake hood | Weather protection | Insect screen and filter |
| Motorized damper | Opens with the hood | Interlocked, not manual |
| Duct | Carries the air | Size for low velocity |
| Filter | Cleans the air | Accessible for service |
| Heater | Tempered air | Required in a cold climate |
| Controller | Balances the system | Pressure or CFM based |
Strategies that work
A dedicated makeup-air unit with a motorized damper, a filter, and a tempering heater is the most reliable solution. A simpler approach is a passive intake with a barometric damper, but it can be drafty and hard to balance. A heat-recovery ventilator can provide fresh air, but it is not sized for a 900 CFM hood.
Do not use a window as the permanent makeup air source. It is uncontrolled, unfiltered, and a security issue. A window can be a temporary test, not a design.
Commissioning and maintenance
Commission the system with a pressure test and a smoke test. Run the hood at high speed and check the pressure in the kitchen and the mechanical room. Confirm the damper opens and closes, the heater works, and the filter is accessible.
Change the filter on schedule and check the damper every year. A stuck damper can turn a good system into a backdraft risk. Keep the commissioning report with the project file.
The installation sequence.
- Record the hood CFM and the appliance fuel types.
- Perform a blower-door test or a pressure test.
- Check the combustion appliances for backdraft risk.
- Calculate the makeup-air requirement with a qualified contractor.
- Choose an interlocked, filtered, tempered system.
- Commission with a pressure test and a smoke test.
- Maintain the filter and the damper annually.
What to remember.
- A hood removes air; the house needs a path for replacement air.
- A tight house can need makeup air at 600 CFM or less.
- A motorized damper interlocked with the hood prevents backdrafts.
- A CO alarm is not a substitute for a pressure test.
Field note
Test the pressure with the hood on high and the clothes dryer running. The worst case is the one that matters, not the best-case test.
The schedule
Guide profile in one table.
The same fields used across the benchmark set, so this guide can be compared with the styles, layouts, and materials it references.
| Field | Value |
|---|---|
| Topic | Ventilation |
| Read time | 4 minutes |
| Sections | 5 |
| Steps | 7 |
| Data tables | 2 |
| Planning cost | $800–$6,000 |
| Install timeline | 3 days |
| Heat / moisture | 8/10 |
| Slip / stain | 8/10 |
| Maintenance | Moderate |
| Ideal room | 80 sq ft–500 sq ft |
| Task light | 3000K |
Apply the guide
Where this rule meets a plan.
The guide is only useful when it meets a measured layout. These combinations apply the same dimensions to a specific style and material schedule.
Japandi / Galley kitchen
001Galley Double-Run Kitchen
- Size
- 9 × 14 ft
- Budget
- $47,450–$121,000
- Build
- 37–73 d
Japandi / L-shaped kitchen
002L-Shaped Kitchen with Island
- Size
- 14 × 16 ft
- Budget
- $62,050–$159,650
- Build
- 41–80 d
Modern Minimalist / Galley kitchen
003Galley Double-Run Kitchen
- Size
- 9 × 14 ft
- Budget
- $49,000–$130,000
- Build
- 41–78 d
Modern Minimalist / L-shaped kitchen
004L-Shaped Kitchen with Island
- Size
- 14 × 16 ft
- Budget
- $64,100–$170,350
- Build
- 41–80 d
Layouts
The trade-offs
What the guide assumes.
Every rule has a boundary. These are the conditions behind this one.
What works
- Makeup air keeps a powerful hood from depressurizing the house.
- A motorized damper prevents backdrafts when the hood is off.
- A filtered intake keeps dust and pollen out of the kitchen.
What to watch
- A tempered makeup-air system adds cost and space.
- A passive intake can be drafty and hard to balance.
- The system needs annual maintenance.
Read next
Related field guides.
The next question is usually one section over.
Kitchen planning / 5 min
G01Work Triangle Leg Dimensions
A measured guide to the sink-cook-fridge triangle, including leg lengths, total travel, obstruction rules, and plan-specific exceptions.
Clearances / 4 min
G02Kitchen Aisle Clearance Standards
A practical guide to kitchen aisle widths, appliance door clearances, seating clearance, and the difference between a code minimum and a comfortable work zone.
Ventilation / 4 min
G03Range Hood CFM & Duct Sizing
A technical guide to hood sizing, capture area, duct velocity, equivalent length, and the ventilation details that make a kitchen work.
FAQ
Ventilation questions.
Practical answers drawn from the specification, cost model, and installation sequence.